For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
质检报告
是
压力最大值(操作时填充床压力)
2 bar (0.2 MPa, 29 psi)
储存
2°C 至 8°C,20% 乙醇
直径:178mm 柱床高度:200mm 包装规格:5L
—
29026927
产品详情
直径:80mm 柱床高度:200mm 包装规格:1L
ReadyToProcess™ MabSelect SuRe™ LX 1 L (80/200)
层析技术
Affinity chromatography
应用
For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
质检报告
是
压力最大值(操作时填充床压力)
2 bar (0.2 MPa, 29 psi)
储存
2°C 至 8°C,20% 乙醇
直径:80mm 柱床高度:200mm 包装规格:1L
—
29376119
产品详情
直径:600mm 柱床高度:200mm 包装规格:57L
ReadyToProcess™ MabSelect SuRe™ LX 57 L (600/200)
层析技术
Antibody affinity chromatography
应用
For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
质检报告
是
压力最大值(操作时填充床压力)
2 bar (0.2 MPa, 29 psi)
储存
2°C 至 8°C,20% 乙醇
直径:600mm 柱床高度:200mm 包装规格:57L
—
29027644
产品详情
直径:126mm 柱床高度:200mm 包装规格:2.5L
ReadyToProcess™ MabSelect SuRe™ LX 2.5 L (126/200)
层析技术
Affinity chromatography
应用
For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
质检报告
是
压力最大值(操作时填充床压力)
2 bar (0.2 MPa, 29 psi)
储存
2°C 至 8°C,20% 乙醇
直径:126mm 柱床高度:200mm 包装规格:2.5L
—
29172004
产品详情
直径:251mm 柱床高度:200mm 包装规格:10L
ReadyToProcess™ MabSelect SuRe™ LX 10 L (251/200)
层析技术
Affinity chromatography
应用
For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
质检报告
是
压力最大值(操作时填充床压力)
2 bar (0.2 MPa, 29 psi)
储存
2°C 至 8°C,20% 乙醇
直径:251mm 柱床高度:200mm 包装规格:10L
—
29172006
产品详情
直径:359mm 柱床高度:200mm 包装规格:20L
ReadyToProcess™ MabSelect SuRe™ LX 20 L (359/200)
层析技术
Affinity chromatography
应用
For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
质检报告
是
压力最大值(操作时填充床压力)
2 bar (0.2 MPa, 29 psi)
储存
2°C 至 8°C,20% 乙醇
直径:359mm 柱床高度:200mm 包装规格:20L
—
29610439
产品详情
直径:359mm 柱床高度:250mm 包装规格:25L
ReadyToProcess™ MabSelect SuRe™ LX 25 L (359/250)
层析技术
Affinity chromatography
应用
For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
质检报告
是
压力最大值(操作时填充床压力)
2 bar (0.2 MPa, 29 psi)
储存
2°C 至 8°C,20% 乙醇
直径:359mm 柱床高度:250mm 包装规格:25L
—
29256260
产品详情
直径:450mm 柱床高度:200mm 包装规格:32L
ReadyToProcess™ MabSelect SuRe™ LX 32 L (450/200)
层析技术
Affinity chromatography
应用
For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
质检报告
是
压力最大值(操作时填充床压力)
2 bar (0.2 MPa, 29 psi)
储存
2°C 至 8°C,20% 乙醇
直径:450mm 柱床高度:200mm 包装规格:32L
—
产品详情
此类层析柱预填充了 MabSelect SuRe™ LX 蛋白 A 填料,用于在生产规模下捕获单克隆抗体 (mAb)。ReadyToProcess™ 层析柱是已经验证的高效生物工艺层析柱,供应时已预填充,可立即使用。