注册
0 ¥0.00
    注册快速订购

MicroFunnel filter funnels

Disposable filter funnels for quality control analysis of aqueous fluids

变体 Array 参考编号: 30050173

(仅支持询价)

变体 Array 参考编号: 30050185

(仅支持询价)

变体 Array 参考编号: 30050138

(仅支持询价)

变体 Array 参考编号: 30050182

(仅支持询价)

变体 Array 参考编号: 30050174

¥1,755.00¥12,656.00

货号 规格描述 价格 数量 操作
4800ME Pore Size (Removal Rating):Other
Funnel Capacity:Other
数量:Other
过滤介质:ME25 mixed cellulose ester
有效过滤面积:13.46 cm²
Cover material:polystyrene
¥3,233.00
4810 Pore Size (Removal Rating):0.2 µm
Funnel Capacity:100 mL
数量:50
过滤介质:GN-6 MCE
有效过滤面积:Other
Cover material:Other
4801ME Pore Size (Removal Rating):Other
Funnel Capacity:Other
数量:Other
过滤介质:ME25 mixed cellulose ester
有效过滤面积:13.46 cm²
Cover material:polystyrene
4810ME Pore Size (Removal Rating):Other
Funnel Capacity:Other
数量:Other
过滤介质:ME25 mixed cellulose ester
有效过滤面积:13.46 cm²
Cover material:polystyrene
4804ME Pore Size (Removal Rating):Other
Funnel Capacity:Other
数量:Other
过滤介质:ME25 mixed cellulose ester
有效过滤面积:13.46 cm²
Cover material:polystyrene
4801 Pore Size (Removal Rating):0.45 µm
Funnel Capacity:100 mL
数量:50
过滤介质:GN-6 MCE
有效过滤面积:Other
Cover material:Other
4818 Pore Size (Removal Rating):0.2 µm
Funnel Capacity:300 mL
数量:20
过滤介质:PES
有效过滤面积:Other
Cover material:Other
4805 Pore Size (Removal Rating):0.45 µm
Funnel Capacity:100 mL
数量:50
过滤介质:Modified PES
有效过滤面积:Other
Cover material:Other
4804 Pore Size (Removal Rating):0.2 µm
Funnel Capacity:100 mL
数量:200
过滤介质:GN-6 MCE
有效过滤面积:Other
Cover material:Other
4803 Pore Size (Removal Rating):0.45 µm
Funnel Capacity:100 mL
数量:50
过滤介质:PES
有效过滤面积:Other
Cover material:Other
4800 Pore Size (Removal Rating):100 mL
Funnel Capacity:100 mL
数量:50
过滤介质:GN-6 MCE
有效过滤面积:Other
Cover material:Other
4815ME Pore Size (Removal Rating):Other
Funnel Capacity:Other
数量:Other
过滤介质:ME25 mixed cellulose ester
有效过滤面积:13.46 cm²
Cover material:polystyrene
4713 Pore Size (Removal Rating):N/A
Funnel Capacity:N/A
数量:1
过滤介质:N/A
有效过滤面积:Other
Cover material:Other
4806 Pore Size (Removal Rating):0.45 µm
Funnel Capacity:100 mL
数量:50
过滤介质:PES
有效过滤面积:Other
Cover material:Other
4815 Pore Size (Removal Rating):0.45 µm
Funnel Capacity:300 mL
数量:20
过滤介质:GN-6 MCE
有效过滤面积:Other
Cover material:Other
4828 Pore Size (Removal Rating):0.45 µm
Funnel Capacity:300 mL
数量:20
过滤介质:PES
有效过滤面积:Other
Cover material:Other
4817 Pore Size (Removal Rating):0.45 µm
Funnel Capacity:300 mL
数量:20
过滤介质:Modified PES
有效过滤面积:Other
Cover material:Other
4896 Pore Size (Removal Rating):N/A
Funnel Capacity:N/A
数量:1
过滤介质:N/A
有效过滤面积:Other
Cover material:Other
4852 Pore Size (Removal Rating):0.45 µm
Funnel Capacity:100 mL
数量:50
过滤介质:PES
有效过滤面积:Other
Cover material:Other
4863 Pore Size (Removal Rating):N/A
Funnel Capacity:N/A
数量:1
过滤介质:N/A
有效过滤面积:Other
Cover material:Other

Microfunnel™ filter funnels, a Pall Life Sciences product, are convenient, ready-to-use disposable filter funnels for quality control analysis of aqueous fluids used in pharmaceutical production, water, and food and beverage applications.

Product performs as sample container and filter funnel all in one. No need to transfer sample from cup to disposable funnel and risk introducing contamination.
MicroFunnel Plus AP unit allows aseptic collection of the sample through the lid sample port. No need to remove lid.
MicroFunnel Plus products with Supor™ membrane are designed to allow sampling of hot water up to 90°C.
Vented lid snaps to a liquid-tight seal and allows filtration without having to open the funnel and risk introducing contamination.
Vent filter ensures no airborne contamination is drawn into the funnel during filtration.
Attaches directly to a standard laboratory manifold or use with adapter and stopper.
Volume graduations are clearly marked for ease in measuring your sample volume.
Individually bagged and labeled for contamination control and lot traceability.
NEW Packaging* see Specifications for more information

Specifications

Materials of Construction

Filter Media: GN-6 Metricel™ (mixed cellulose esters), Supor™(hydrophilic polyethersulfone), and Metricel™ Black (modified polyethersulfone) membranes
Support Pad: Cellulose
Funnel and Base: Polypropylene
Adhesive Gasket: Urethane
Funnel Cover: Polyethylene with hydrophobic Versapor™ membrane (acrylic copolymer on a non-woven support)
Bag: Polyethylene
Adapter: Polyethylene
Plug: Polyethylene (PN 4807, 4808)

Effective Filtration Area

13.46 cm2

Dimensions

100 mL Funnel

Height: 7.6 cm (3.0 in.) with cover
Diameter: 6.1 cm (2.4 in.) with cover

300 mL Funnel
Height: 8.9 cm (3.5 in.)
Diameter: 8.7 cm (3.4 in.)

 

Maximum Vacuum

63.5 cm Hg (25 in. Hg) (vacuum use only)
Maximum Sample Collection Temperature
PN 4807, 4808, 4829: Ambient
PN 4809, 4814, 4823, 4843, and 4844: 90°C (194°F)

Gamma-Irradiated

Validated dose 15 – 30 kGy

New Improved Packaging!

No mistakes—clearly labeled
Easy to peal—hermetically sealed
Secure during shipment—thermoform pack

Applications

Improves the efficiency of monitoring your water system while reducing the introduction of contamination.
Eliminates steps in sample collection and testing that could potentially contaminate your sample.
Gridded 0.45 μm GN-6 Metricel™ membrane is ideal for analysis of ambient water by Membrane Filter (MF) Technique.
MicroFunnel Plus with 0.45 or 0.2 μm Supor™ membrane is designed for sampling hot water (such as that found in hot loop WFI systems).

Performance

How to Use the MicroFunnel Plus Filter Funnel

Sampling Ambient Water

    1. Carefully remove the vented lid and collect the sample.
    1. Securely snap lid in place to prevent sample loss. Transport sample to laboratory for filtration.
    1. Remove membrane vent from base, place funnel directly onto manifold, and filter the sample.
    1. Gently grasp funnel then remove and discard lid.
    1. Release cylinder from base by squeezing the midpoint of the cylinder.
    Remove the membrane, plate the filter, and incubate.

Collecting Hot Water Samples

    1. Place funnel into holder with graduations visible through the viewing slot. Carefully remove the vented lid and collect the hot water sample.
    With funnel and holder resting on a firm, level surface, securely snap lid in place to prevent sample loss. Remove funnel from holder and transport sample to laboratory for filtration. (Proceed with steps 3-6 for ambient water.)

安全数据表搜索

搜索安全数据表文件。

证书搜索

搜索证书分析文件(CoA),质量标准(CoQ),符合性证书(CoC)

    0
    购物车
    购物车是空的回到商城