注册快速订购

VacuCap & VacuCap PF vacuum filtration devices

Innovative bottle-top filters for fast vacuum filtration of aqueous solutions

变体 Array 参考编号: 40017073

变体 Array 参考编号: 40017072

变体 Array 参考编号: 40017070

变体 Array 参考编号: 40063603

变体 Array 参考编号: 40017683

变体 Array 参考编号: 40017682

变体 Array 参考编号: 40017681

变体 Array 参考编号: 40017071

变体 Array 参考编号: 40064181

变体 Array 参考编号: 40017680

变体 Array 参考编号: 40017069

¥1,394.42 – ¥3,550.46

货号 描述 价格 数量 操作
4624
库存紧张
Media membrane:Supor Hydrophilicpolyethersulfone
孔径:0.45 µm
连接:3 over 4 hose barb inner taper in
有效过滤面积:60 cm²
¥1,394.42
4622
现货
Media membrane:Supor Hydrophilicpolyethersulfone
孔径:0,2
连接:2 over 4 hose barb inner taper in
有效过滤面积:60 cm²
¥1,797.83
4623 Media membrane:Other
孔径:Other
连接:Other
有效过滤面积:Other
¥1,833.99
TA4622
现货
Media membrane:Supor Hydrophilicpolyethersulfone
孔径:0,2
连接:9 over 4 hose barb inner taper in
有效过滤面积:60 cm²
¥1,859.98
4634 Media membrane:Supor Hydrophilicpolyethersulfone
孔径:0.45 µm
连接:7 over 4 hose barb inner taper in
有效过滤面积:30 cm²
¥2,424.98
4632 Media membrane:Supor Hydrophilicpolyethersulfone
孔径:0,2
连接:6 over 4 hose barb inner taper in
有效过滤面积:30 cm²
¥2,424.98
TA4632 Media membrane:Supor Hydrophilicpolyethersulfone
孔径:0,2
连接:10 over 4 hose barb inner taper in
有效过滤面积:30 cm²
¥2,484.87
4638 Media membrane:Supor Hydrophilicpolyethersulfone
孔径:0.8/0.2 µm
连接:8 over 4 hose barb inner taper in
有效过滤面积:30 cm²
¥3,326.72
4631 Media membrane:Supor Hydrophilicpolyethersulfone
孔径:0.1 µm
连接:5 over 4 hose barb inner taper in
有效过滤面积:30 cm²
¥3,326.72
4628 Media membrane:Supor Hydrophilicpolyethersulfone
孔径:0.8/0.2 µm
连接:4 over 4 hose barb inner taper in
有效过滤面积:60 cm²
¥3,550.46
4621 Media membrane:Supor Hydrophilicpolyethersulfone
孔径:0.1 µm
连接:1/4 hose barb inner taper in
有效过滤面积:60 cm²
¥3,550.46

VacuShield™ & VacuShield™ PF vacuum filtration devices, a Pall Life Sciences product, are innovative bottle-top filters for fast vacuum filtration of 100 mL to 5 L of aqueous solutions.

Replace current vacuum filter systems
Simplify workflow
Maximize filtration
Filter faster. Supor™ membrane provides high flow rates.
No need to constantly refill upper fluid reservoir.
Draws directly from the mixing reservoir.
Eliminates the possibility of contamination from transfer steps. Filters directly into the desired container.
Match filter to sample volume by choosing from two sizes.
Available built-in prefilter increases throughput of particulate-laden solutions such as serum-containing media.
Environmentally-friendly with minimal plastic waste.
Patented small design accepts a variety of collection vessels and reduces storage space and waste.
TA version available with tubing attached to each device for maximum convenience.
Gamma irradiated, eliminates potential contamination by EtO residuals

Materials of Construction

Filter Media: Supor™[hydrophilic polyethersulfone (PES)] membrane
Housing: Modified acrylic
Membrane Support Material: Polyester
Sinker Material: Glass-filled polyurethane elastomer
Inlet Tubing: Polyvinyl chloride (PVC) medical-grade tubing
Gasket Seal Material: Polyethylene

Pore Size

0.1, 0.2, 0.45, and 0.8/0.2 μm

Effective Filtration Area

VacuCap™ 60 Devices: 30 cm2
VacuCap™ 90 Devices: 60 cm2

Typical Throughput

(RPMI + 10% newborn calf serum)

VacuCap™ 60 Devices, 0.2 μm: 1 L
VacuCap™ 90 Devices, 0.2 μm: 5 L

(RPMI + 10% calf serum)
VacuCap™ 60 PF Devices: 500 mL
VacuCap™ 90 PF Devices: 1 L

 

Collection Vessel

VacuCap™ 60 Devices: Can be used on receptacles with openings ranging from 2 – 5 cm (0.8 – 1.9 in.)
VacuCap™ 90 Devices: Can be used on receptacles with openings ranging from 2 – 6.5 cm (0.8 – 2.5 in.)
Warning: Collection vessels should be vacuum rated. Implosion may result.

Typical Hold-Up Volume

VacuCap™ 60 Devices: 1.2 mL
VacuCap™ 90 Devices: 3.2 mL

Maximum Operating Temperature

55°C (131°F)

Recommended Vacuum

38.1 cm Hg (15 in. Hg)
VacuCap™ 60 Devices

0.1 µm: 50
0.2 µm: 200
0.45 µm: 280
PF: 200

VacuCap™ 90 Devices
0.1 µm: 100
0.2 µm: 400
0.45 µm: 560
PF: 400

 

Endotoxin Level

< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test

Biological Safety

Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>

Sterilization

Sterilized by gamma irradiation and individually packaged

Application

Excellent device for cell culture media preparation
PF version is useful for sterilization of hard-to-filter solutions
Reduce mycopalsma with the 0.1 µm pore size

View our video on vacuum filtration made easy

Materials of Construction

Filter Media: Supor™[hydrophilic polyethersulfone (PES)] membrane
Housing: Modified acrylic
Membrane Support Material: Polyester
Sinker Material: Glass-filled polyurethane elastomer
Inlet Tubing: Polyvinyl chloride (PVC) medical-grade tubing
Gasket Seal Material: Polyethylene

Pore Size

0.1, 0.2, 0.45, and 0.8/0.2 μm

Effective Filtration Area

VacuCap™ 60 Devices: 30 cm2
VacuCap™ 90 Devices: 60 cm2

Typical Throughput

(RPMI + 10% newborn calf serum)
VacuCap™ 60 Devices, 0.2 μm: 1 L
VacuCap™ 90 Devices, 0.2 μm: 5 L
(RPMI + 10% calf serum)
VacuCap™ 60 PF Devices: 500 mL
VacuCap™ 90 PF Devices: 1 L

Collection Vessel

VacuCap™ 60 Devices: Can be used on receptacles with openings ranging from 2 – 5 cm (0.8 – 1.9 in.)
VacuCap™ 90 Devices: Can be used on receptacles with openings ranging from 2 – 6.5 cm (0.8 – 2.5 in.)
Warning: Collection vessels should be vacuum rated. Implosion may result.

Typical Hold-Up Volume

VacuCap™ 60 Devices: 1.2 mL
VacuCap™ 90 Devices: 3.2 mL
Maximum Operating Temperature 55°C (131°F)

Recommended Vacuum

38.1 cm Hg (15 in. Hg)

Endotoxin Level

< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test

Biological Safety

Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>

Sterilization

Sterilized by gamma irradiation and individually packaged

Application

Excellent device for cell culture media preparation
PF version is useful for sterilization of hard-to-filter solutions
Reduce mycopalsma with the 0.1 µm pore size

安全数据表搜索

搜索安全数据表文件。

证书搜索

搜索证书分析文件(CoA),质量标准(CoQ),符合性证书(CoC)

    0
    购物车
    购物车是空的回到商城